Display : 3 1/2 digits LCD display, maximum reading value display 1999 .Ranges: 1-50,000Lux. Resolution: 1Lux .Accuracy: ≤10,000Lux: ±4%rdg±0.5f.s ≥10,000Lux:±5%+10digits .Repeatability: ±2% .Temperature Characteristic: ±0.1%/℃ .Test rate: 0.4 sec. Photo detector: one silicon photo diode with filter. Dimension: 165×67×32mm .Weight: approx. 155 g (including battery) .
Temperature Range -30℃~550℃Accuracy ±2℃ or ±2%Distance Spot Ratio 12:1Emissivity adjustable √alarm temperature set √Maximum / minimum value √meanvalue √
SPECIFICATION Input Voltage AC220V±10%Output Voltage 0~30VOutput Current 0~2A Source Effect ≤0.01%±2mV ≤0.02%±3mALoad Effect ≤0.01%±5mVRipple & Noise ≤1mVrms ≤3mArmsDisplay LCDDisplay Accuracy ±1%±1 Operation temperature :-10℃~40℃:<90%Deposited Condition :-20℃~80℃ :<80%
Measuring scope 0.01mA~300.0A(50/60Hz)Accuracy 0.01mAAccuracy(below 23℃±1℃,70%RH) 0.00mA~9.99mA: ±1.2%±5dgt 10.0mA~300.0mA: ±1.5%±5dgt0.00A~9.99A: ±1.2%±5dgt 10.0A~99.9A: ±1.5%±5dgt100.0A~199.9A: ±2%±5dgt 200.0A~300.0A: ±4%±5dgtMeasuring range 30mA/300mA,30A/300A,second-range manual switch,automatic switch in all ranges Clamp mouth φ40mmPower supply DC3V Button-type battery LR-44×2 or SR-44×2Test mode Clip-on CT,integral mode Display mode Four Bits LCD displayDimension Width × Height× Thickness;64mm×160mm×23mmLCD mimension 35mm×21.5mm;display domain;32mm×15mmLine voltage Line test under AC600VSampling rate about 2 times/sData storage 60 groups, “FU” symbol flickering means storage is fullPeak holding Peak value capture and holding function, press HOLD button continually to show peak value in the course of testing.Data holding Data holding function;displayed by “DH” symbolOverflow display Outrange overflow display;displayed by “OL” symbolAutomatic shutdown After starting up the leaker for 5 minutes, it will shut down automatically to reduce battery consumption.Battery voltage When battery voltage reduced to 2.5V~2.7V, battery low voltage symbol will filker to remind replacing battery; at this time, measurement accuracy will decrease.Leaker quality About 120g(with battery)Working temperature and humidity -0℃~40℃;below 80%rhStorage temperature and humidity -10℃~60℃;below 70%rhInsulation strength AC2kV/rms (between core and box)Rating power About 5mWApplicable safety rules IEC1010-1、IEC1010-2-032、pollution, etc 2、CAT Ⅲ(600V)Packing Clamp tester: 1pcs, Box: 1pcs, Rope chain:1pcs
Range Measuring Range Acceleration:0.1-199.9m/S2 peak(rms*v2) Velosity:0.1-1999.9mm/s rms Displacement:0.001-1.999mm p-p(rms*2v2) Accuracy ±5%±2digits Frequency Response Acceleration:10Hz-1KHz(LO) 1KHz-15KHz(HI) Velosity/Displacement: 10Hz-1KHz